Product Summary

8-Port IEC61850-3 Certified Industrial Rack-Mount Secure Modbus Gateway, DSub-9 or TB5 connectors, Optional 3kV Serial Isolation, Dual Power input Remotely access Modbus RTU/ASCII devices, convert to...
(100 items available)

Product Description

8-Port IEC61850-3 Certified Industrial Rack-Mount Secure Modbus Gateway, DSub-9 or TB5 connectors, Optional 3kV Serial Isolation, Dual Power input
  • Remotely access Modbus RTU/ASCII devices, convert to Modbus TCP
  • Supporting advanced Modbus Features. Configuration via Web Browser
  • IEC61850-3 certified, can be easily set up into IEC61850-3 substations
  • Industrial EMC protection, wide temperature operation, -40°C~80°C
  • Redundant Power Input for fault protection, either 24~48 VDC or High-Voltage AC/DC (100~240VAC or 100~370VDC)
  • 6 Fast-Ethernet interfaces, either RJ45 or SFP slot
  • 8 RS-232/RS-485/RS-422 Serial ports, with or without isolation
  • Supporting VirtualCOM, embedded security with IPsec VPN
  • Configuration via Web Browser/ Serial Console / Telnet/ Windows Utility
  • Automatic mapping of all slaves’ data into memory, up to 64 connections
Diverse Hardware Infrastructure Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in front of the device. Industrial EMC protection makes MB5908A ready for every mission. Security and Redundancy MB5908A embeds OpenVPN and IPsec VPN, that allows you to tunnel your data securely throught the internet and prevent unauthorized control of your Serial Devices by malicious people. The integrated Rapid Spanning Tree Protocol (RSTP), allows you to add a backup Ethernet link in the event the primary one fails. Switching between Modbus Protocols Modbus Gateway supports the standard Modbus protocol and is capable of converting any Modbus protocols between Modbus TCP, Modbus RTU, and Modbus ASCII for all supported hardware interfaces. All of this, in bidirectional mode: Ethernet and Serial ends can selected to be either master or slave. Modbus ID Routing Modbus Gateway supports various types of hardware communication interfaces, Modbus protocol conversion, and Modbus ID routing. Therefore the Modbus Gateway can integrate your existing and complex Modbus hardware configuration into a simple network that can be easily managed. Modbus Data Concentrator The Modbus Data Concentrator performs pre-defined Modbus commands to read/write data from the slave devices via serial ports. It mirrors slave device data to its own memory. Therefore, requesting masters can receive response in a shorter period, achieving better overall efficiency. Regular Modbus gateway   Modbus Concentrator      
The ATOP MB5908A-CT Series stands out with its industrial durability and reliability. With an expansive temperature range of -40°C to +80°C, it can operate confidently even in harsh working conditions. The IP30 protection class ensures the device is safeguarded against dust and splashing water, while the DIN-Rail mounting option allows for easy installation. The redundant power input guarantees uninterrupted operation, continuing to provide service even in the event of a power supply failure. Ideal for industrial applications in Turkey, the MB5908A-CT Series is also notable for its ability to integrate various Modbus devices. These features solidify ATOP’s position as a leading choice in the industry.

Technical Specifications

EMC FCC Part 15, Subpart B, Class A, EN 55032, Class A, EN 61000-6-2, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-4, IEC 61850-3 / IEEE 1613
MTBF MB5916A-6SFP-Sis-HV: 9.18 years; MB5916A-6SFP-Sis: 8.63 years
RoHS Yes
v1.0 SE-MB-PG5900A-08A-16A Certifications LVD
v1.1 Datasheet EN
v1.2 Datasheet EN
v1.3 SE5908-SE5916A-MB5908A-MB5916A-PG5900A-PG5908A-PG5916A Hardware Installation Guide
v1.5 MB59XX CT User Manual
Ports 16
Speed IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X)
v1.71 MB59xx CT Firmware
Parity None, Odd, Even, Space, Mark
Safety EN61010-1, EN 61010-2-201
Weight 3,000g (8-port version); 3,200 g (16-port version)
GDC-120 59906861G
Housing IP30, SPCC housing
LAN Mode Dual Subnets or Network Redundancy
Warranty 5 years
Baud Rate 1,200 ~ 921,600 bps software selectable
Connector 10-Pin Terminal Block
Data Bits 5, 6, 7, 8 software selectable
Isolation 2.5 kV (Sis versions only)
Protocols IPv4, ICMP, TCP, UDP, DHCP Client, SNMPv1,v2c,v3, HTTP, HTTPS, Telnet, RFC2217, 802.1D-2004 RSTP, Security through OpenVPN Client/Server or IPsec VPN (peer-to-peer or peer-to-side) with up to 37.9Mbps VPN throughput, PPTP, and SMTP/TLS
SDR-75-24 50500752240001G
Stop Bits 1, 2 software selectable
MB5908A CT Contact ATOP headquarters
VirtualCOM Windows/Linux redirection software
Flow Control None, Xon/Xoff, RTS/CTS
Installation 19’’ Rack-Mount (Kit included)
Reset Button Yes
Configuration Atop Management Utility, Web UI, Telnet
IEC 61000-4-2 ESD
IEC 61000-4-3 RS
IEC 61000-4-4 EFT
IEC 61000-4-5 Surge
IEC 61000-4-6 CS
IEC 61000-4-8 PFMF
Input Current 0.73 A @ 24 VDC 0.35 A @ 100 VAC 0.20 A @ 100 VDC
MB5908A-HV CT Industrial 8-Port Modbus Concentrator, DB9(M), RS- 232/422/485, RJ45, dual pwr input
MB5908A-TB CT Industrial 8-Port Modbus Concentrator, Terminal Block, RS-232/422/485, RJ45, dual pwr input
ADP-DB9(F)-TB5 59906231G
AXFD-1314-0523 522AXFD1314001G
AXFD-1314-0553 522AXFD1314011G
IEC 61000-4-11 DIP
MB5908A-Sis CT Block, RS-232/422/485, 3kV Isolation, RJ45, dual
Connector ports 2x 10/100BASE-T(X) RJ-45
MB5908A-6SFP CT Industrial 8-Port Modbus Concentrator, DB9(M), RS- 232/422/485, SFP, dual pwr input
MB5908A-TB-HV CT Industrial 8-Port Modbus Concentrator, Terminal Block, RS-232/422/485, RJ45, dual pwr input
Power Redundancy Yes
MB5908A-Sis-HV CT Block, RS-232/422/485, 3kV Isolation, RJ45, dual
Power Consumption Approximately 20 W (Max)
MB5908A-6SFP-HV CT Industrial 16-Port Modbus Concentrator, DB9(M), RS-232/422/485, SFP, dual pwr input
MB5908A-6SFP-TB CT Industrial 8-Port Modbus Concentrator, Terminal Block, RS-232/422/485, SFP, dual pwr input
Input Voltage Range Redundant 19.2-52.8 VDC or Redundant 85-264 VAC/ 100-370 VDC (HV Series)
MB5908A-6SFP-Sis CT Industrial 8-Port Modbus Concentrator, Terminal Block, RS-232/422/485, 3kV Isolation, SFP, dual pwr
Modbus concentrator Optional - please ask your ATOP Representative
Storage Temperature -40°C~85°C (-40°F~185°F)
Rated Supply Voltage Redundant 24-48 VDC or Redundant 100-240 VAC/ 100-370 VDC (HV Series)
Dimension (W x H x D) 436 mm x 43.5 mm x 200 mm
MB5908A-6SFP-TB-HV CT Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, SFP, dual pwr input
Operating Temperature -40°C~80°C (-40°F~176°F)
MB5908A-6SFP-Sis-HV CT Industrial 16-Port Modbus Concentrator, Terminal Block, RS-232/422/485, 3kV Isolation, SFP, dual pwr
Ambient Relative Humidity 5%~95%, 55°C (Non-condensing)
Reverse Polarity Protection Yes
Modbus redundant concentrator Optional - please ask your ATOP Representative
Modbus Gateway Supported Modes Ethernet: Modbus TCP Server/Client(or VCOM); Serial: Modbus RTU/ASCII (master/slave)
Shock Drop (Freefall) Vibration MIL-STD-810F Method 516.5 MIL-STD-810F Method 516.5 MIL-STD-810F Method 514.5 C1 & C2
Maximum number of Modbus clients/slaves Modbus TCP: Maximum 16 clients; Maximum 32 slave connections
Brand ATOP
Model MB5908A-CT Series - ATOP
Main Category Atop

Shipping & Returns Information

Shipping Information

  • Shipped within 2-3 business days
  • Free shipping over 500 TL
  • Insured shipping

Return & Exchange

  • 14 days return right
  • Return in original packaging
  • Fast processing guarantee