PG5900A Series - ATOP
In Stock (100 items)
266 views
€0,00
VAT Included
Product Summary
IEC61850-3 Certified Smart Grid Protocol Gateway
Compliant with IEC 61850-3 and IEEE 1613 Power Substation StandardsOptional Full-License version for simultaneous transformation of multiple protocolsI...
Product Description
IEC61850-3 Certified Smart Grid Protocol Gateway
- Compliant with IEC 61850-3 and IEEE 1613 Power Substation Standards
- Optional Full-License version for simultaneous transformation of multiple protocols
- Isolated redundant power inputs with 24-48 VDC ,100-240 VAC, 100-370 VDC
- Extreme EMC protection according to IEC61850-3. Works in environments from -40 to +80°C
- Same hardware platform for different protocol conversion (Modbus TCP, DNP3.0 over Ethernet, IEC 60870-5-104, IEC 61850)
- User friendly configuration with a Java-Based Windows utility
- Embedded PPTP, IPsec and OpenVPN client/server for enhanced security
- Network Redundancy through RSTP
Product Description
The PG5900A Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different Ethernet-based protocols. The IEDs communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.
The configuration carried out through a user friendly, Java- Based Windows Utility called eNode Designer, that allows configuring target platforms, set device properties and protocol data mapping. The configuration is completely dependent on the “eNode Module” which represents that device or application – but may include things such as changing the communication port settings and defining where data point information enters and leaves the eNode Designer system.
PG5900A Series embeds an additional layer of security, allowing the devices to be deployed in topologies that request data to flow through the Internet and preventing sensitive control and monitoring data to be readable from malicious activities. IPsec VPN encryption, configurable in both peer-to-peer and peer-to-side modes will make sure the data passing is encrypted through a strong 128, 192 or 256-bit AES encryption. OpenVPN-based applications can take advantage of Client/Server support on our device.
An additional highlight of ATOP protocol gateways is the ability to enable multiple protocols simultaneously. In contrast to conventional gateways, which require predefinition of a single master and slave protocol each, the Full-License model allows users to transform multiple incoming protocols in our protocol base to others compatible with the output side, achieving powerful protocol conversion functions, flexible operations, and easier maintenance.
The protocol gateway’s embedded protocol stacks allow
- Seamless conversion
- Exception/error Management
- Unsolicited event management for the protocols requiring them (such as DNP3)
- High performance
- Low cost
The example shows how to Easily connect a Modbus Serial HMI, through Atop’s Protocol Gateway to a DNP3.0 Ethernet Server IED. The host HMI has the role of a Modbus Serial Master while the end-device to be accessed is a DNP3.0 Ethernet Server.
Atop’s protocol Gateway acts towards the HMI seamlessly as a Modbus Serial Slave, answering the poll commands or the write commands required by the Host by its virtual Modbus ID. Meanwhile, it acts as a DNP3.0 Ethernet Client with regard to the end-device whose DNP3.0 address is mapped to the virtual Modbus ID that the HMI is accessing.
Be careful! – all gateway functions listed in the datasheet refer to the “Gateway” role, and not which “host” or “slave” the gate way is connected to. In this example, the SKU shown is “MBSS-DNEC” (Modbus Serial Slave to DNP3.0 Ethernet Client)
The ATOP PG5900A Series stands out with its industrial durability and reliability. With an extensive temperature range of -40°C to +75°C, it ensures uninterrupted performance even in harsh environmental conditions, while its IP30 protection class provides defense against dust and moisture. Additionally, the DIN-Rail mounting option and redundant power input enhance the system's continuity and safety. The PG5900A is an excellent choice for industrial applications in Turkey, enabling seamless conversion of various protocols. These features make it an ideal solution for energy facilities, automation systems, and other critical infrastructure projects.
Technical Specifications
| FL | Allows a model to run single or multiple protocol(s) in both front-end to SCADA and back-end to IED sides |
| EMC | FCC Part 15, Subpart B, Class A, EN 55032, Class A, EN 61000-6-2, EN 61000-3-2, EN 61000- 3-3, EN 55024, EN 61000-6-4, IEC 61850-3 / IEEE 1613 |
| MTBF | PG5900A: 16.60 years PG5916A-6SFP-Sis-HV: 9.18 years PG5916A-6SFP-Sis: 8.63 years |
| RoHS | Yes |
| v1.0 | SE-MB-PG5900A-08A-16A Certifications LVD |
| v1.4 | PG5900A Hardware Installation Guide |
| v1.5 | eNode-Designer-User-Manual-103-Atop |
| v1.6 | eNode-Designer-User-Manual-IEC61850-Atop |
| v1.8 | Getting started with Atop PG and eNode Designer |
| v2.0 | eNode designer - Caution: PG59xx v0.66 and the older version should use eNode v1.31 |
| Shock | MIL-STD-810F Method 516.5 |
| Speed | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) - RJ45 version IEEE 802.3u 100Base-FX - SFP version |
| v1.00 | PG59XX Full-License |
| v1.31 | eNode designer - Support PG59xx v0.66 and the older version |
| v5.20 | Management Utility for Windows |
| v5.60 | Management Utility for Windows |
| Safety | EN61010-1, EN 61010-2-201 |
| Weight | 4,000g |
| GDC-120 | 59906861G |
| Housing | IP30 SPCC housing |
| PG5900A | Industrial Protocol Gateway,10/100BASE-T(X) RJ45, 24-48 VDC |
| Warranty | SE5916A-6SFP-Sis-HV: 9.18 years SE5916A-6SFP-Sis: 8.63 years PG5900A / PG5908A / PG5916A: 5 years |
| 04ES-50EC | IEC 60870-5-104 Ethernet Server to IEC 61850 Ethernet Client |
| 04ES-DNEC | IEC 60870-5-104 Ethernet Server to DNP3 Ethernet Client |
| 04ES-MBEC | IEC 60870-5-104 Ethernet Server to Modbus Ethernet Client |
| 50ES-04EC | IEC 61850 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| 50ES-DNEC | IEC 61850 Ethernet Server to DNP3 Ethernet Client |
| 50ES-MBEC | IEC 61850 Ethernet Server to Modbus Ethernet Client |
| Connector | 10-Pin Terminal Block |
| DNES-04EC | DNP3 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| DNES-50EC | DNP3 Ethernet Server to IEC 61850 Ethernet Client |
| DNES-MBEC | DNP3 Ethernet Server to Modbus Ethernet Client |
| MBES-04EC | Modbus Ethernet Server to IEC 60870-5-104 Ethernet Client |
| MBES-50EC | Modbus Ethernet Server to IEC 61850 Ethernet Client |
| MBES-DNEC | Modbus Ethernet Server to DNP3 Ethernet Client |
| Protocols | IPv4, ARP, ICMP, TCP, UDP, DHCP Client, DNS Client, Telnet, HTTP, HTTPS, SMTP/TLS, SNMP v1/v2c/v3, Syslog, 802.1D-2004 RSTP, OpenVPN or IPsec VPN (peer-to-peer or peer-to-side), with a maximum VPN throughput of 37.9Mbps(*), and PPTP |
| SDR-75-24 | 50500752240001G |
| Vibration | MIL-STD-810F Method 514.5 C1 & C2 |
| PG5900A-HV | Industrial Protocol Gateway,10/100BASE-T(X) RJ45, 100-240VAC/ 100-370VDC |
| Installation | 19’’ Rack-Mount (Kit included) |
| Network mode | Independent IP address (6 ports) or Independent IP address (4 ports) + Unmanaged Switch (3 ports, including LAN4) |
| PG5900A-6SFP | Industrial Protocol Gateway,10/100BASE-T(X) SFP slot, 24-48 VDC |
| Reset Button | Yes |
| ADP-DB9(F)TB5 | 59906231G |
| Configuration | Atop Management Utility, Web UI, Telnet, Serial Console, ATOP eNode Designer |
| IEC 61000-4-2 | ESD |
| IEC 61000-4-3 | RS |
| IEC 61000-4-4 | EFT |
| IEC 61000-4-5 | Surge |
| IEC 61000-4-6 | CS |
| IEC 61000-4-8 | PFMF |
| Input Current | 0.73 A @ 24 VDC 0.35 A @ 100 VAC 0.20 A @ 100 VDC |
| AXFD-1314-0523 | 522AXFD1314001G |
| AXFD-1314-0553 | 522AXFD1314011G |
| IEC 61000-4-11 | DIP |
| Connector ports | RJ45 x 6 (RJ45 version) SFP x 6 (SFP version) |
| Drop (Freefall) | MIL-STD-810F Method 516.5 |
| PG5900A-6SFP-HV | Industrial Protocol Gateway,10/100BASE-T(X) SFP slot, 100-240VAC/ 100-370VDC |
| Power Redundancy | Yes |
| Protocol setting | eNode designer |
| Power Consumption | Approximately 20 W (Max) |
| Input Voltage Range | Redundant 19.2-52.8 VDC or Redundant 85-264 VAC/ 100-370 VDC (HV Series) |
| Storage Temperature | -40°C~85°C (-40°F~185°F) |
| Supported Protocols | Modbus TCP/RTU/ASCII, DNP3.0 over serial and TCP/IP, IEC61850, IEC60870-5-101, IEC60870-5-103, IEC60870-5-104 |
| Rated Supply Voltage | Redundant 24-48 VDC or Redundant 100-240 VAC/ 100-370 VDC (HV Series) |
| Dimension (W x H x D) | 440.6 x 44 x 309 mm (1U Rack-mount) |
| Operating Temperature | -40°C~80°C (-40°F~176°F) |
| Protocol specifications | Refer to datasheet |
| Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
| Reverse Polarity Protection | Yes |
| Brand | ATOP |
| Model | PG5900A Series - ATOP |
| Main Category | Atop |
Shipping & Returns Information
Shipping Information
- Shipped within 2-3 business days
- Free shipping over 500 TL
- Insured shipping
Return & Exchange
- 14 days return right
- Return in original packaging
- Fast processing guarantee