PG5904D Series - ATOP
In Stock (100 items)
249 views
€0,00
VAT Included
Product Summary
4-Port RS232/485/422 and 2 x Fast-Ethernet or Gigabit RJ45, DNP3.0, Modbus, IEC 60870-5-101/103/104, IEC 61850 Smart Grid Protocol Gateway
Dual 10/100 Mbps Ethernet port, with optional PoE PD or 100/1...
Product Description
4-Port RS232/485/422 and 2 x Fast-Ethernet or Gigabit RJ45, DNP3.0, Modbus, IEC 60870-5-101/103/104, IEC 61850 Smart Grid Protocol Gateway
- Dual 10/100 Mbps Ethernet port, with optional PoE PD or 100/1000 Mbps SFP Slot
- 4-port RS-232/422/485, baud rate up to 921.6 Kbps, D-Sub9 or Terminal Block, Optional 3kV Serial Isolation
- IP30 Metal housing with Aluminum heat sink
- Redundant DC power input, one Relay Output
- Strong EMC protection, works in environments from -40 to 85°C
- Same hardware platform for different protocol conversion (Modbus TCP/RTU/ASCII, DNP3.0 TCP or serial, IEC 60870-5-101, IEC 60870-5-103, IEC 60870-5-104, IEC 61850)
- Optional Full-License version for simultaneous transformation of multiple protocols
- User friendly configuration with a Java-Based Windows utility
- Embedded PPTP, IPsec VPN or OpenVPN for enhanced security
Product Description
The PG59XX Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.
The configuration carried out through a use friendly, Java- Based Windows Utility called eNode Designer. It allows configuring target platforms, set device properties and protocol data point mapping. To do so, a project file representing the system should be created. This will include devices and the protocol applications running on them. The configuration is completely dependent on the “eNode Module” which represents that device or application – but may include things such as changing the communication port settings and defining where data point information enters and leaves the eNode Designer system.
PG59XX Series embeds an additional layer of security, allowing the devices to be deployed in topologies that request data to flow through the Internet and preventing sensitive control and monitoring data to be readable from malicious activities. IPsec VPN encryption, configurable in both peer-to-peer and peer-to-side modes will make sure the data passing is encrypted through a strong 128, 192 or 256-bit AES encryption.
An additional highlight of ATOP protocol gateways is the ability to enable multiple protocols simultaneously. In contrast to conventional gateways, which require predefinition of a single master and slave protocol each, the Full-License model allows users to transform multiple incoming protocols in our protocol base to others compatible with the output side, achieving powerful protocol conversion functions, flexible operations, and easier maintenance.
ApplicationThe protocol gateway’s embedded protocol stacks allow
- Seamless conversion
- Exception/error Management
- Unsolicited event management for the protocols requiring them (such as DNP3)
- High performance
- Low cost
The example shows how to Easily connect a Modbus Serial HMI, through ATOP’s Protocol Gateway to a IEC60870-5-101 Serial Slave RTU. The host HMI has the role of a Modbus Serial Master while the end-device to be accessed is a IEC60870-5-101 Serial Slave.
ATOP’s protocol Gateway acts towards the HMI seamlessly as a Modbus Serial Slave, answering the poll commands or the write commands required by the Host by its virtual Modbus ID. Meanwhile, it acts as a IEC60870-5-101 Serial Master, with regard to the end-device whose 101 address is mapped to the virtual Modbus ID that the HMI is accessing.
Be careful! – all gateway functions listed in the datasheet refer to the “Gateway” role, and not which “host” or “slave” the gateway is connected to. In this example, the SKU shown is “MBSS-01SM” (Modbus Serial Slave to IEC60870-5-101 Serial Master)
The ATOP PG5904D Series stands out for its industrial durability and reliability. With an extensive temperature range from -40°C to +75°C, it ensures dependable performance even in harsh environmental conditions. The IP30 protection class safeguards against dust and water, while the DIN-Rail mounting option allows for easy installation. Redundant power input guarantees uninterrupted operation, and ATOP's multiple protocol conversion features make it an excellent solution for industrial applications in Turkey. This capability allows seamless transitions between different protocols, optimizing your data communication and enhancing your operational efficiency.
Technical Specifications
| FL | Allows a model to run single or multiple protocol(s) in both front-end to SCADA and back-end to IED sides |
| EMC | FCC Part 15, Subpart B, Class A EN 55032, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-2, EN 61000-6-4 |
| MTBF | 14.56 Years (according to MIL-HDBK-217F) |
| Mode | RS-232/422/485, software selectable |
| RoHS | Yes |
| v1.0 | SE-MB-PG5904D Certifications UL |
| v1.1 | SE5904D/MB5904D/PG5904D Hardware Installation Guide |
| v1.5 | eNode-Designer-User-Manual-103-Atop |
| v1.6 | eNode-Designer-User-Manual-IEC61850-Atop |
| v1.8 | Getting started with Atop PG and eNode Designer |
| v2.0 | eNode designer - Caution: PG59xx v0.66 and the older version should use eNode v1.31 |
| v2.3 | Datasheet EN |
| Ports | 4 |
| Shock | MIL-STD-810G Method 516.7 |
| Speed | USB 2.0 |
| v1.00 | PG59XX Full-License |
| v1.31 | eNode designer - Support PG59xx v0.66 and the older version |
| v5.20 | Management Utility for Windows |
| v5.60 | Management Utility for Windows |
| Parity | None, Odd, Even |
| Safety | IEC/EN 61010-1, UL61010-1, IEC/EN 61010-2-201, UL61010-2-201, EN62368-1 |
| Weight | 1,000g |
| GDC-120 | 59906861G |
| Housing | IP30 SPCC housing |
| LAN Mode | Dual Subnets or Network Redundancy |
| Warranty | 5 Years |
| 01SS-03SM | IEC 60870-5-101 Serial Slave to IEC 60870-5-103 Serial Master |
| 01SS-04EC | IEC 60870-5-101 Serial Slave to IEC 60870-5-104 Ethernet Client |
| 01SS-50EC | IEC 60870-5-101 Serial Slave to IEC 61850 Client |
| 01SS-DNEC | IEC 60870-5-101 Serial Slave to DNP3 Ethernet Client |
| 01SS-DNSM | IEC 60870-5-101 Serial Slave to DNP3 Serial Master |
| 01SS-MBEC | IEC 60870-5-101 Serial Slave to Modbus Ethernet Client |
| 01SS-MBSM | IEC 60870-5-101 Serial Slave to Modbus Serial Master |
| 04ES-01SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-101 Serial Master |
| 04ES-03SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-103 Serial Master |
| 04ES-50EC | IEC 60870-5-104 Ethernet Server to IEC 61850 Ethernet Client |
| 04ES-DNEC | IEC 60870-5-104 Ethernet Server to DNP3 Ethernet Client |
| 04ES-DNSM | IEC 60870-5-104 Ethernet Server to DNP3 Serial Master |
| 04ES-MBEC | IEC 60870-5-104 Ethernet Server to Modbus Ethernet Client |
| 04ES-MBSM | IEC 60870-5-104 Ethernet Server to Modbus Serial Master |
| 50ES-01SM | IEC 61850 Ethernet Server to IEC 60870-5-101 Serial Master |
| 50ES-03SM | IEC 61850 Ethernet Server to IEC 60870-5-103 Serial Master |
| 50ES-04EC | IEC 61850 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| 50ES-DNEC | IEC 61850 Ethernet Server to DNP3 Ethernet Client |
| 50ES-DNSM | IEC 61850 Ethernet Server to DNP3 Serial Master |
| 50ES-MBEC | IEC 61850 Ethernet Server to Modbus Ethernet Client |
| 50ES-MBSM | IEC 61850 Ethernet Server to Modbus Serial Master |
| Baud Rate | 1,200~921,600 bps |
| Connector | 7-Pin 5.08mm Lockable Terminal Block |
| DNES-01SM | DNP3 Ethernet Server to IEC 60870-5-101 Serial Master |
| DNES-03SM | DNP3 Ethernet Server to IEC 60870-5-103 Serial Master |
| DNES-04EC | DNP3 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| DNES-50EC | DNP3 Ethernet Server to IEC 61850 Ethernet Client |
| DNES-DNSM | DNP3 Ethernet Server to DNP3 Serial Master |
| DNES-MBEC | DNP3 Ethernet Server to Modbus Ethernet Client |
| DNES-MBSM | DNP3 Ethernet Server to Modbus Serial Master |
| DNSS-01SM | DNP3 Serial Slave to IEC 60870-5-101 Serial Master |
| DNSS-03SM | DNP3 Serial Slave to IEC 60870-5-103 Serial Master |
| DNSS-04EC | DNP3 Serial Slave to IEC 60870-5-104 Ethernet Client |
| DNSS-50EC | DNP3 Serial Slave to IEC 61850 Ethernet Client |
| DNSS-DNEC | DNP3 Serial Slave to DNP3 Ethernet Client |
| DNSS-MBEC | DNP3 Serial Slave to Modbus Ethernet Client |
| DNSS-MBSM | DNP3 Serial Slave to Modbus Serial Master |
| Data Bits | 7,8 |
| Isolation | 2 KV |
| MBES-01SM | Modbus Ethernet Server to IEC 60870-5-101 Serial Master |
| MBES-03SM | Modbus Ethernet Server to IEC 60870-5-103 Serial Master |
| MBES-04EC | Modbus Ethernet Server to IEC 60870-5-104 Ethernet Client |
| MBES-50EC | Modbus Ethernet Server to IEC 61850 Ethernet Client |
| MBES-DNEC | Modbus Ethernet Server to DNP3 Ethernet Client |
| MBES-DNSM | Modbus Ethernet Server to DNP3 Serial Master |
| MBSS-01SM | Modbus Serial Slave to IEC 60870-5-101 Serial Master |
| MBSS-03SM | Modbus Serial Slave to IEC 60870-5-103 Serial Master |
| MBSS-04EC | Modbus Serial Slave to IEC 60870-5-104 Ethernet Client |
| MBSS-50EC | Modbus Serial Slave to IEC 61850 Client |
| MBSS-DNEC | Modbus Serial Slave to DNP3 Ethernet Client |
| MBSS-DNSM | Modbus Serial Slave to DNP3 Serial MasterMBSS-MBEC |
| Protocols | IPv4, ARP, ICMP, TCP, UDP, DHCP Client, DNS Client, Telnet, HTTP, HTTPS, SMTP/TLS, SNMP v1/v2c/v3, Syslog, 802.1D-2004 RSTP, OpenVPN or IPsec VPN (peer-to-peer or peer-to-side), with a maximum VPN throughput of 37.9Mbps(*), and PPTP |
| SDR-75-24 | 50500752240001G |
| Stop Bits | 1,2 |
| USB Ports | 1 |
| Vibration | MIL-STD-810G Method 514.7 |
| Installation | DIN-Rail , Wall mount (optional kit) |
| Relay Output | 1A @ 30 VDC (normal open) |
| Reset Button | Yes |
| Configuration | Atop Management Utility, Web UI, Telnet, Serial Console, ATOP eNode Designer |
| IEC 61000-4-2 | ESD |
| IEC 61000-4-3 | RS |
| IEC 61000-4-4 | EFT |
| IEC 61000-4-5 | Surge |
| IEC 61000-4-6 | CS |
| IEC 61000-4-8 | PFMF |
| Input Voltage | Dual 12 - 48VDC (non-PoE Models); or through Ethernet Cable (PoE versions) |
| LM28-C3S-TI-N | 50708031G |
| LM38-C3S-TI-N | 50709411G |
| LS38-C3L-TI-N | 50709441G |
| LS38-C3S-TI-N | 50709391G |
| PG5904D-4P-DB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X), DB9 |
| PG5904D-4P-TB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X), TB5 |
| WMK-450-Black | 70100000000052G |
| ADP-DB9(F)-TB5 | 59906231G |
| PG5904D-4P-Sis | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X), Isolation |
| Connector ports | 2x 10/100BASE-T(X) RJ-45 or 2x 100/1000 Base-X SFP Slots (SFP version) |
| Drop (Freefall) | MIL-STD-810G Method 516.7 |
| Power Redundancy | Yes |
| Protocol setting | eNode designer |
| PG5904D-4P-PoE-DB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) with PoE, DB9 |
| PG5904D-4P-PoE-TB | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) with PoE, TB5 |
| Power Consumption | Approximately 8 W (Max) |
| PG5904D-4P-PoE-Sis | Industrial 4-Port Protocol Gateway, 10/100BASE-T(X) With PoE, Isolation |
| PG5904D-4P-G-DB-SFP | Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, DB9 |
| PG5904D-4P-G-TB-SFP | Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, TB5 |
| Storage Temperature | -40°C~85°C (-40°F~185°F) |
| Supported Protocols | Modbus TCP/RTU/ASCII, DNP3.0 over serial and TCP/IP, IEC61850, IEC60870-5-101, IEC60870-5-103, IEC60870-5-104 |
| PG5904D-4P-G-Sis-SFP | Industrial 4-Port Protocol Gateway, 100/1000BASE-X with SFP Slot, Isolation |
| Dimension (W x H x D) | 55 x 145 x 113 mm |
| Operating Temperature | -40°C~85°C (-40°F~185°F) |
| PoE standard supported | IEEE 802.3 af (-PoE version only) |
| Input Current (@ 12VDC) | 0.65 A @ 12 VDC |
| Protocol specifications | Refer to datasheet |
| CBL-RJ45(8P)-DB9(F)-90-C | 50891971G |
| Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
| Reverse Polarity Protection | Yes |
| Brand | ATOP |
| Model | PG5904D Series - ATOP |
| Main Category | Atop |
Shipping & Returns Information
Shipping Information
- Shipped within 2-3 business days
- Free shipping over 500 TL
- Insured shipping
Return & Exchange
- 14 days return right
- Return in original packaging
- Fast processing guarantee