PG5908 Series - ATOP
In Stock (100 items)
224 views
€0,00
VAT Included
Product Summary
8-Port RS232/485/422 with RJ45 and 2-Port Fast-Ethernet, DNP3, Modbus, IEC 60870-5-101/103/104, IEC 61850, Smart Grid Protocol Gateway
Dual 10/100Mbps Ethernet ports, Embedded PPTP, IPsec or OpenVPN f...
Product Description
8-Port RS232/485/422 with RJ45 and 2-Port Fast-Ethernet, DNP3, Modbus, IEC 60870-5-101/103/104, IEC 61850, Smart Grid Protocol Gateway
- Dual 10/100Mbps Ethernet ports, Embedded PPTP, IPsec or OpenVPN for enhanced security
- Remotely monitor, manage, and control industrial field devices
- Relay out indicator for Network link-status
- LCM display with 4-key touch pad for configuration
- Same hardware platform for different protocol conversion (Modbus TCP/ RTU/ASCII, DNP3.0 TCP or serial, IEC 60870-5-101, IEC 60870-5-103, IEC 60870-5-104, IEC 61850)
- Optional Full-License version for simultaneous transformation of multiple protocols
- User friendly configuration with a Java-Based Windows utility
- Integrated RSTP redundancy
Product Description
The PG5908 Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.
The configuration carried out through a use friendly, Java- Based Windows Utility called eNode Designer. It allows configuring target platforms, set device properties and protocol data point mapping. To do so, a project file representing the system should be created. This will include devices and the protocol applications running on them. The configuration is completely dependent on the “eNode Module” which represents that device or application – but may include things such as changing the communication port settings and defining where data point information enters and leaves the eNode Designer system.
PG5908 Series embeds an additional layer of security, allowing the devices to be deployed in topologies that request data to flow through the Internet and preventing sensitive control and monitoring data to be readable from malicious activities. IPsec VPN encryption, configurable in both peer-to-peer and peer-to-side modes will make sure the data passing is encrypted through a strong 128, 192 or 256-bit AES encryption.
An additional highlight of ATOP protocol gateways is the ability to enable multiple protocols simultaneously. In contrast to conventional gateways, which require predefinition of a single master and slave protocol each, the Full-License model allows users to transform multiple incoming protocols in our protocol base to others compatible with the output side, achieving powerful protocol conversion functions, flexible operations, and easier maintenance.
ApplicationThe protocol gateway’s embedded protocol stacks allow
- Seamless conversion
- Exception/error Management
- Unsolicited event management for the protocols requiring them (such as DNP3)
- High performance
- Low cost
The example shows how to Easily connect a Modbus Serial HMI, through ATOP’s Protocol Gateway to a DNP3.0 IED. The host HMI has the role of a Modbus Serial Master while the end-device to be accessed is a DNP3.0 Ethernet Server.
ATOP’s protocol Gateway acts towards the HMI seamlessly as a Modbus Serial Slave, answering the poll commands or the write commands required by the Host by its virtual Modbus ID. Meanwhile, it acts as a DNP3.0 Ethernet Client, with regard to the end-device whose DNP3.0 address is mapped to the virtual Modbus ID that the HMI is accessing.
Be careful! – all gateway functions listed in the datasheet refer to the “Gateway” role, and not which “host” or “slave” the gateway is connected to. In this example, the SKU shown is “MBSS-DNEC” (Modbus Serial Slave to DNP3.0 Ethernet Client)
The ATOP PG5908 Series stands out as a robust protocol gateway designed for industrial applications. With an extensive operating temperature range of -40°C to +75°C, it ensures reliable performance even in harsh environmental conditions. Its IP30 protection class enhances the unit's resilience against external factors, while the DIN-Rail mounting option facilitates easy installation and integration. Moreover, the redundant power input provides an added layer of security against power interruptions, making it an ideal solution for uninterrupted operations in industrial facilities across Turkey. The multi-protocol support offered by the PG5908 Series allows users to seamlessly integrate various industrial communication standards, solidifying its position as an indispensable tool in the Turkish industrial sector.
Technical Specifications
| FL | Allows a model to run single or multiple protocol(s) in both front-end to SCADA and back-end to IED sides |
| EMC | FCC Part 15, Subpart B, Class A EN 55032, Class A EN 61000-3-2 EN 61000-3-3 EN 55024 |
| Drop | ISTA Test Procedure 2A |
| Fuse | 50709441G |
| MTBF | PG5908-SiS-DC: 19.00 years; PG5908-SiS-US/EU: 19.03 years PG5916-SiS-DC: 13.38 years; PG5916-SiS-US/EU: 13.38 years |
| Mode | RS-232/422/485, software selectable |
| v1.0 | Tcpdump for diagnosis |
| v1.5 | eNode-Designer-User-Manual-103-Atop |
| v1.6 | eNode-Designer-User-Manual-IEC61850-Atop |
| v1.8 | Getting started with Atop PG and eNode Designer |
| v2.0 | SE5908/MB5908/PG5908 Hardware Installation Guide |
| Ports | 8 |
| Shock | IEC 60068-2-27 |
| v1.00 | PG59XX Full-License |
| v1.31 | eNode designer - Support PG59xx v0.66 and the older version |
| v5.20 | Management Utility for Windows |
| v5.50 | Management Utility for Windows |
| Parity | None, Odd, Even |
| RoHS 2 | Yes |
| Safety | EN60950-1:2006; EN62368-1 |
| Weight | 3,000g (8-port version); 3,200 g (16-port version) |
| GDC-120 | 59906861G |
| Housing | IP30, SPCC housing |
| LAN Mode | Dual Subnets or RSTP LAN Redundancy |
| Warranty | 5 Years |
| 01SS-03SM | IEC 60870-5-101 Serial Slave to IEC 60870-5-103 Serial Master |
| 01SS-04EC | IEC 60870-5-101 Serial Slave to IEC 60870-5-104 Ethernet Client |
| 01SS-50EC | IEC 60870-5-101 Serial Slave to IEC 61850 Client |
| 01SS-DNEC | IEC 60870-5-101 Serial Slave to DNP3 Ethernet Client |
| 01SS-DNSM | IEC 60870-5-101 Serial Slave to DNP3 Serial Master |
| 01SS-MBEC | IEC 60870-5-101 Serial Slave to Modbus Ethernet Client |
| 01SS-MBSM | IEC 60870-5-101 Serial Slave to Modbus Serial Master |
| 04ES-01SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-101 Serial Master |
| 04ES-03SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-103 Serial Master |
| 04ES-50EC | IEC 60870-5-104 Ethernet Server to IEC 61850 Ethernet Client |
| 04ES-DNEC | IEC 60870-5-104 Ethernet Server to DNP3 Ethernet Client |
| 04ES-DNSM | IEC 60870-5-104 Ethernet Server to DNP3 Serial Master |
| 04ES-MBEC | IEC 60870-5-104 Ethernet Server to Modbus Ethernet Client |
| 04ES-MBSM | IEC 60870-5-104 Ethernet Server to Modbus Serial Master |
| 50ES-01SM | IEC 61850 Ethernet Server to IEC 60870-5-101 Serial Master |
| 50ES-03SM | IEC 61850 Ethernet Server to IEC 60870-5-103 Serial Master |
| 50ES-04EC | IEC 61850 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| 50ES-DNEC | IEC 61850 Ethernet Server to DNP3 Ethernet Client |
| 50ES-DNSM | IEC 61850 Ethernet Server to DNP3 Serial Master |
| 50ES-MBEC | IEC 61850 Ethernet Server to Modbus Ethernet Client |
| 50ES-MBSM | IEC 61850 Ethernet Server to Modbus Serial Master |
| Baud Rate | 1,200 ~ 921,600 bps |
| Connector | IEC 60320-1 C14 AC Power Inlet (AC models) 5.08mm 3-pin Lockable Terminal Block (DC models) |
| DNES-01SM | DNP3 Ethernet Server to IEC 60870-5-101 Serial Master |
| DNES-03SM | DNP3 Ethernet Server to IEC 60870-5-103 Serial Master |
| DNES-04EC | DNP3 Ethernet Server to IEC 60870-5-104 Ethernet Client |
| DNES-50EC | DNP3 Ethernet Server to IEC 61850 Ethernet Client |
| DNES-DNSM | DNP3 Ethernet Server to DNP3 Serial Master |
| DNES-MBEC | DNP3 Ethernet Server to Modbus Ethernet Client |
| DNES-MBSM | DNP3 Ethernet Server to Modbus Serial Master |
| DNSS-01SM | DNP3 Serial Slave to IEC 60870-5-101 Serial Master |
| DNSS-03SM | DNP3 Serial Slave to IEC 60870-5-103 Serial Master |
| DNSS-04EC | DNP3 Serial Slave to IEC 60870-5-104 Ethernet Client |
| DNSS-50EC | DNP3 Serial Slave to IEC 61850 Ethernet Client |
| DNSS-DNEC | DNP3 Serial Slave to DNP3 Ethernet Client |
| DNSS-MBEC | DNP3 Serial Slave to Modbus Ethernet Client |
| DNSS-MBSM | DNP3 Serial Slave to Modbus Serial Master |
| Data Bits | 5, 6, 7, 8 |
| MBES-01SM | Modbus Ethernet Server to IEC 60870-5-101 Serial Master |
| MBES-03SM | Modbus Ethernet Server to IEC 60870-5-103 Serial Master |
| MBES-04EC | Modbus Ethernet Server to IEC 60870-5-104 Ethernet Client |
| MBES-50EC | Modbus Ethernet Server to IEC 61850 Ethernet Client |
| MBES-DNEC | Modbus Ethernet Server to DNP3 Ethernet Client |
| MBES-DNSM | Modbus Ethernet Server to DNP3 Serial Master |
| MBSS-01SM | Modbus Serial Slave to IEC 60870-5-101 Serial Master |
| MBSS-03SM | Modbus Serial Slave to IEC 60870-5-103 Serial Master |
| MBSS-04EC | Modbus Serial Slave to IEC 60870-5-104 Ethernet Client |
| MBSS-50EC | Modbus Serial Slave to IEC 61850 Client |
| MBSS-DNEC | Modbus Serial Slave to DNP3 Ethernet Client |
| MBSS-DNSM | Modbus Serial Slave to DNP3 Serial MasterMBSS-MBEC |
| PG5908-DC | Ind. 8-Port Protocol Gateway,RS-232/422/485 Software Selectable, DC TB3 |
| PG5908-EU | Ind. 8 Port Protocol Gateway, RS-232/422/485 Software Selectable, AC Inlet, EU Plug |
| PG5908-US | Ind. 8 Port Protocol Gateway, RS-232/422/485 Software Selectable, AC Inlet, US Plug |
| Protocols | IPv4, ARP, ICMP, TCP, UDP, DHCP Client, DNS Client, Telnet, HTTP, HTTPS, SMTP/TLS, SNMP v1/v2c/v3, Syslog, RSTP, OpenVPN or IPsec VPN (peer-to-peer or peer-to-side), with a maximum VPN throughput of 37.9Mbps(*), and PPTP |
| SDR-75-24 | 50500752240001G |
| Stop Bits | 1, 2 |
| Vibration | IEC 60068-2-64 |
| Compliance | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) |
| Installation | 19’’ Rack-Mount (Kit included) |
| Reset Button | Yes |
| Ethernet Port | 2x RJ-45 |
| IEC 61000-4-2 | ESD |
| IEC 61000-4-3 | RS |
| IEC 61000-4-4 | EFT |
| IEC 61000-4-5 | Surge |
| IEC 61000-4-6 | CS |
| IEC 61000-4-8 | PFMF |
| PG5908-SiS-DC | Ind. 8 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, DC TB3 |
| PG5908-SiS-EU | Ind. 8 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, AC Inlet, EU Plug |
| PG5908-SiS-US | Ind. 8 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, AC Inlet, US Plug |
| RMK-718-Black | 70100000000040G |
| IEC 61000-4-11 | DIP |
| Power Cable (EU) | 50801051G |
| Power Cable (US) | 50801041G |
| Power Redundancy | No |
| Power Consumption | 0.54A @ 24 VDC 0.21A @ 100 VAC |
| Input Voltage Range | DC version: 24-48VDC; US-EU version: 90-264 VAC (EU or US Plug) |
| Storage Temperature | -40°C~85°C (-40°F~185°F) |
| Rated Supply Voltage | DC version: 24-48VDC; US-EU version: 100-240 VAC (EU or US Plug) |
| Dimension (W x H x D) | 436 mm x 43.5 mm x 200 mm |
| Operating Temperature | -20°C~70°C (-4°F~158°F) |
| CBL-RJ45(8P)-DB9(F)-90 | 50891791G |
| CBL-RJ45(8P)-DB9(M)-90 | 50891781G |
| CBL-RJ45(8P)-DB9(M)-200 | 50891951G |
| Protocol specifications | Refer to datasheet |
| CBL-RJ45(8)-DB9(F)-200-C | 50891961G |
| CBL-RJ45(8P)-DB9(F)-90-C | 50891971G |
| Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
| Reverse Polarity Protection | Yes (DC version only) |
| Power Adapter AD17-24C (US-Y) | 50500151240002G |
| Power Adapter AD17-24D (EU-Y) | 50500151240012G |
| Brand | ATOP |
| Model | PG5908 Series - ATOP |
| Main Category | Atop |