The NG06 direct operated directional control valve D1VW with inductive position control provides high functional limits up to 80 l/min in combination with a low, energy saving pressure drop. It is typ...
Product Description
The NG06 direct operated directional control valve D1VW with inductive position control provides high functional limits up to 80 l/min in combination with a low, energy saving pressure drop. It is typically used in safety relevant applications.
Parker’s direct operated directional control valve series D1VW with inductive position control in NG06 (CETOP 03 / NFPA D03) features low energy losses due to optimized flow passages. It offers high functional limits up to 80 l/min and a maximum pressure of 350 bar.
This on/off valve is typically used in safety relevant applications. It complies with the machinery directive 2006/42/EG for use as clamping valve according to EN 201:2010. The start or the end position can be monitored. The position control is available for single and double solenoid valves.
Markets:
• Industrial
• Molding
Features/Benefits:
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide product offering – many different options – all valves from one single source
• Short delivery time – no warehousing necessary
Applications:
• All types of safety relevant applications
• Injection molding (safety component according to machinery directive 2006/42/EG)
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by Parker.
The fail-safe position of the directional valve during power failure is the spring offset or center position.
This on/off valve is typically used in safety relevant applications. It complies with the machinery directive 2006/42/EG for use as clamping valve according to EN 201:2010. The start or the end position can be monitored. The position control is available for single and double solenoid valves.
Markets:
• Industrial
• Molding
Features/Benefits:
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide product offering – many different options – all valves from one single source
• Short delivery time – no warehousing necessary
Applications:
• All types of safety relevant applications
• Injection molding (safety component according to machinery directive 2006/42/EG)
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by Parker.
The fail-safe position of the directional valve during power failure is the spring offset or center position.
The Parker D1VW020HNJWI4N Series is a direct-acting directional control valve equipped with inductive position control, designed to ensure safety and efficiency in industrial applications. This directional control valve offers high functional limits of up to 80 l/min while providing effective pressure drop and low energy consumption. It is particularly critical for automation systems, robotic applications, and hydraulic systems, functioning efficiently within a wide temperature range of -20 °C to +50 °C. The use of NBR material ensures durability and long-lasting performance. Manufactured in compliance with international standards, these valves from Parker are an ideal choice for industrial enterprises seeking reliability and high performance. The D1VW series is designed to enhance workforce efficiency and ensure operational safety in various applications.
Technical Specifications
| Weight | 1.8 kg |
| Function | 2-way |
| Spool Code | 020 |
| Body Material | Cast Iron |
| Configuration | Directional spool valve |
| Input Voltage | 24 V DC |
| Mounting Type | Sub-base, Manifold |
| Seal Material | NBR |
| Actuation Type | Solenoid |
| For Fluid Type | Hydraulic Oil According to DIN 51524 |
| Spool Position | 2 positions, spring offset in position a, operated in position b |
| Port Connection | NG06 / CETOP 03 |
| Solenoid Option | With manual override |
| Maximum Flow Rate | 70 L/min |
| Position Control Type | Start position monitored side A |
| Filter Efficiency Rating | ISO 4406; 18/16/13 |
| Maximum Fluid Temperature | 70 °C |
| Minimum Fluid Temperature | -20 |
| Maximum Operating Pressure | P, A, B: 350 bar, T: 210 bar |
| Maximum Ambient Temperature | 60 °C |
| Maximum Kinematic Viscosity | 400 cSt |
| Minimum Ambient Temperature | -25 °C |
| Minimum Kinematic Viscosity | 2.8 cSt |
| Maximum Operating Temperature | 60 °C |
| Minimum Operating Temperature | -20 °C |
| Brand | Parker |
| Model | Directional Control Valve with Inductive Position Control - Series D1VW - D1VW020HNJWI4N |
| SKU | D1VW020HNJWI4N |
| Main Category | Parker |
Shipping & Returns Information
Shipping Information
- Shipped within 2-3 business days
- Free shipping over 500 TL
- Insured shipping
Return & Exchange
- 14 days return right
- Return in original packaging
- Fast processing guarantee