Pilot Operated Proportional Reducing Valve - Series VMY - VMY160K06NN1P
SKU:
VMY160K06NN1P
In Stock (15 items)
57 views
€0,00
VAT Included
Product Summary
Proportional pressure reducing valves series VMY in size NG06 and NG10 allow the variable adjustment of the reduced pressure from 0 bar up to the nominal pressure.
Product Description
Proportional pressure reducing valves series VMY in size NG06 and NG10 allow the variable adjustment of the reduced pressure from 0 bar up to the nominal pressure.
Working extremely precise, Parker's proportional pressure reducing valves of the series VMY in size NG06 or NG10 improve the process accuracy of hydraulic applications. They provide a variable adjustment of the reduced pressure from 0 bar up to the nominal pressure.
The valve consists of a spool type main stage and a proportionally operated pilot stage. The desired pressure can be variably set corresponding to the command signal specified on the amplifier. The proportional solenoid converts the current of the amplifier into force on the valve poppet of the pilot stage.
Typical applications are pressure systems, test equipment, or counterweight systems. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400 for open loop systems or with PWDXXA-40* for closed loop systems.
Markets:
• Industrial
• Machine tools
Features/Benefits:
• Works very precise - for high process accuracy
• High oscillation stability - preserves the material and improves the product quality
• 5 pressure stages - enables fine adjustment
• Short delivery time for most variations - no warehousing necessary
Applications:
• Suitable for general hydraulic applications
• Machine tools
Function VMY*K06:
With the proportional solenoids de-energized, the main spring forces the main spool into the neutral position. Port A is connected to port T. Thus the reduced pressure only depends on the back pressure in the external drain pipe and/or the tank pressure and can accordingly be reduced down to 0 bar. The pressure present in the P line delivers the pilot oil to the pilot stage via a flow control valve.
When the proportional solenoid is energized, the pilot pressure is increased in the pilot pressure area, and the main spool moves against the spring until the connection P - A opens. The regulation of the reduced pressure on connection A takes place by the constant comparison of the actual pressure and the reference pressure of the pilot stage.
Function VMY*K10:
The valve spool is designed so that the connection B-A is open in the neutral position and is closed in the working position.
The valve consists of a spool type main stage and a proportionally operated pilot stage. The desired pressure can be variably set corresponding to the command signal specified on the amplifier. The proportional solenoid converts the current of the amplifier into force on the valve poppet of the pilot stage.
Typical applications are pressure systems, test equipment, or counterweight systems. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400 for open loop systems or with PWDXXA-40* for closed loop systems.
Markets:
• Industrial
• Machine tools
Features/Benefits:
• Works very precise - for high process accuracy
• High oscillation stability - preserves the material and improves the product quality
• 5 pressure stages - enables fine adjustment
• Short delivery time for most variations - no warehousing necessary
Applications:
• Suitable for general hydraulic applications
• Machine tools
Function VMY*K06:
With the proportional solenoids de-energized, the main spring forces the main spool into the neutral position. Port A is connected to port T. Thus the reduced pressure only depends on the back pressure in the external drain pipe and/or the tank pressure and can accordingly be reduced down to 0 bar. The pressure present in the P line delivers the pilot oil to the pilot stage via a flow control valve.
When the proportional solenoid is energized, the pilot pressure is increased in the pilot pressure area, and the main spool moves against the spring until the connection P - A opens. The regulation of the reduced pressure on connection A takes place by the constant comparison of the actual pressure and the reference pressure of the pilot stage.
Function VMY*K10:
The valve spool is designed so that the connection B-A is open in the neutral position and is closed in the working position.
The Parker VMY Series Pilot Operated Proportional Reducing Valve - VMY160K06NN1P offers a reliable pressure control solution for industrial automation systems. Available in NG06 and NG10 sizes, this proportional reducing valve allows for precise adjustment of reduced pressure from 0 bar to nominal pressure. Constructed from NBR material, it performs effectively even in a temperature range of -20 °C.
This valve is particularly suitable for hydraulic systems and pneumatic applications, providing essential pressure control and regulation. Designed in accordance with industry standards, the Parker VMY160K06NN1P helps users enhance system efficiency and achieve energy savings. Its high durability and precision make it a preferred choice in various applications across the industrial sector.
Technical Specifications
| Brand | Parker |
| Media | Hydraulic Oil |
| Weight | 2.8 kg |
| Marking | Standard |
| Division | Industrial Systems Division Europe |
| Function | Proportional |
| Industry | Industrial Manufacturing Equipment |
| Flow Rate | 40 L/min |
| Technology | Hydraulics |
| Valve Type | Proportional pressure reducing valve |
| Application | Industrial Hydraulic |
| Body Material | Steel |
| Mounting Type | Subplate mounting |
| Seal Material | NBR |
| Actuation Type | Proportional |
| For Fluid Type | Hydraulic Oil |
| Mounting Style | ISO 5781 |
| Operation Type | Pilot |
| Product Series | Pressure valve |
| Port Connection | NG06 / CETOP 03 |
| Maximum Flow Rate | N/A |
| Mounting Position | Unrestricted |
| Specifications Met | ISO 7368 |
| Operating Temperature | -20 to 50 °C |
| Pressure Control Range | Internal / external |
| Filter Efficiency Rating | ISO 4406; 18/16/13 |
| Maximum Pressure Setting | 160 bar |
| Maximum Fluid Temperature | 70 °C |
| Minimum Fluid Temperature | -25 °C |
| Maximum Operating Pressure | 315 bar |
| Maximum Ambient Temperature | 60 °C |
| Minimum Ambient Temperature | -25 °C |
| Maximum Operating Temperature | 60 °C |
| Minimum Operating Temperature | -20 °C |
| Pilot Inlet / Drain Locations | 160 bar |
| Brand | Parker |
| Model | Pilot Operated Proportional Reducing Valve - Series VMY - VMY160K06NN1P |
| SKU | VMY160K06NN1P |
| Main Category | Parker |
Shipping & Returns Information
Shipping Information
- Shipped within 2-3 business days
- Free shipping over 500 TL
- Insured shipping
Return & Exchange
- 14 days return right
- Return in original packaging
- Fast processing guarantee