Compact interlock with locking for the protection of process (power-to-lock), 1 x 5 pin M12 connector
The HGL-610A1-A compact interlock from Fortress Safety is a high-quality solution designed to ensure safety in industrial processes. Equipped with a robust locking mechanism, this product helps you protect your critical operations. Made from FDA Food Contact Compliant PBT and UL 94V-2 polycarbonate, the HGL-610A1-A stands out for its durability and safety features. With a voltage capacity of 60V, this interlock boasts protection classes IP65, IP67, and IP69, making it highly resistant to water and dust. Its operational temperature range of -20°C to +55°C (-4°F to +131°F) makes it ideal for harsh industrial environments. The 1 x 5 pin M12 connector allows for quick and easy installation. The HGL-610A1-A meets industrial safety standards, enhancing security in your workplace. Choose Fortress Safety for a safe, efficient, and sustainable working environment.

Technical Specifications

PFH 4.16×10-9
Monitor 200mA Limit
Features Power-to-Lock
Vibration Tested in accordance with GS-ET-19 and BS EN 60947-5-2
Environment Indoor, Washdown
Part Number HGL-610A1-A
Safety Inputs 3.5mA Draw Each
Safety Outputs 50mA Limit Each
Seal Materials FDA Food Contact Compliant Silicon Rubber (ref. 21 CFR 177-2600)
Solenoid Drive 3.5mA Draw
Mechanical Life 1,000,000 Operations
Holding Force Fa 5 – 8 kN
Maximum Altitude 2000m
Product Features Guard Locking
Voltage Drop, Ud <3.5V
Housing Materials 316 Stainless Steel and CF8M Stainless Steel Casting(s)
Off-State Current <0.5mA
Plastic Materials FDA Food Contact Compliant PBT and UL 94V-2 Polycarbonate
Ingress Protection IP65, IP67, IP69
Ambient Temperature -20°C * to +55°C (-4°F to +131°F)
Diagnostic Coverage A maximum DC of 99% can be achieved with suitable monitoring.
Holding Force FZh a 6 – 9.2 kN
Applicable Standards BS EN 62061, EN 60947-5-2, EN ISO 13849, IEC 61508, ISO 14119
Overvoltage Category Type 2
Safety Response Time <200ms
Operating Voltage, Ue 24V DC (+/- 10%)
To Meet UL Requirements The device must be connected to a Limited Voltage/Current Circuit A 4A fuse must be fitted to the device power supply
Minimum Actuating Radius 150 mm
Rated Operating Currents 400mA
Maximum Relative Humidity 50% at 70°C
Category (ISO 13849-1:2015) Up to Cat.4
Maximum Actuating Frequency 720 Operations per Hour
Minimum Operational Current 100mA
Rated Insulation Voltage, Ui 60V
SIL (according to IEC 62061) Up to SIL CL4